Substation Load Management for Electric Power Distribution's Sustainability
Keywords:
distribution transformer, load management, phase imbalance, transformer substation, sustainable power distribution, transformer load factorAbstract
In Nigeria, perhaps due to lack of conscious and planned preventive maintenance culture coupled with inadequate measuring equipment, power system equipment such as transformers are not adequately monitored for preventive maintenance. As a result, most are left to work until a breakdown occurs. Poor loading and uneven distributions are also common phenomena in many of these distribution transformers. Hence, there is a frequent power outage and supply interruption. This paper reports daytime monitoring of voltage, current and apparent power from three transformer substations at Federal Polytechnic Ilaro, Nigeria, to ascertain loading and transformer conditions. The study involved data acquisition of the parameters of interest (voltage, current and apparent power) using Lutron DW 6095 power harmonic analyzer for 2-4 hours with 5 min logging interval. The data analysis was carried out using the computer system. The range of loading conditions encountered was: Substation 1: 75.00?80.60 kVA which was 15?16.14 % of transformer rating; Substation 2: 73.70?90.30 kVA representing 14.74?18.08 % of the transformer rating; Substation 3: 19.04?19.28 kVA representing 3.81?3.85% of the rated transformer capacity. Load factors of 0.97, 0.87, and 0.99 were obtained for the three substations respectively indicating that energy usage was relatively constant during the period under consideration. An ANOVA test at a 5% significant level on each transformer phase current reading yielded F-values of 4475.38, 859.92 and 239117.68 respectively for the substation transformers indicating a huge level of imbalance in the transformer loading. Load balancing is recommended for a sustainable electric power distribution in the locality.
Downloads
Published
Issue
Section
License
Terms and conditions of Creative Commons Attribution 4.0 International License apply to all published manuscripts. This Journal is licensed under a Creative Commons Attribution 4.0 International License. This licence allows authors to use all articles, data sets, graphics and appendices in data mining applications, search engines, web sites, blogs and other platforms by providing appropriate reference. The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
A competing interest exists when professional judgment concerning the validity of research is influenced by a secondary interest, such as financial gain. We require that our authors reveal all possible conflicts of interest in their submitted manuscripts.
The Editor reserves the right to shorten and adjust texts. Significant changes in the text will be agreed with the Authors.